This sf6 gas insulated ring main unit (rmu) three-phase is designed for compact medium-voltage ring network distribution where reliable switching, feeder flexibility, and practical installation footprint are required. It supports urban distribution, RMU-integrated substations, renewable feeders, and project-oriented automation options.

Spécifications techniques

Tension nominale 24 kV
Frequency 50 Hz / 60 Hz
Phase Three Phase
Structure Type Ring main unit (RMU)
Type d'isolation SF6 gas insulation
Norme IEC / GB / customized project specification
Installation Indoor / outdoor according to enclosure design
Application Distribution substations / industrial plants / building electrical systems

Pricing & Availability

Reference FOB Price

USD 5200

Public Marketplace Range

$3,900 – $8,600

Based on public listings. Often lead-generation or minimum-config prices — not full-scope.

Minimum Order

1 Set

Units in Stock

5

Model / Series

SF6

Indicative export reference only. Final offer depends on voltage, standards, materials, accessories, and project scope. Request a firm quote →

Informations sur le produit

Statut

Publié

ID du produit

24KV_SF6_GAS_INSULATED_RING_MAIN_UNIT_RMU_THREE_PHASE

Dernière mise à jour

2026-04-06 00:58:39.208396

Technical Highlights

  • This product combines structured cabinet design, practical electrical coordination, and project-specific configuration flexibility. It is suitable for power systems that need reliable switching or control performance, organized maintenance access, and scalable options for monitoring, communication, and protection.

Application Scenarios

  • Utility feeder control systems
  • Substations and transformer stations
  • Industrial plants and process power systems
  • Urban distribution networks
  • Renewable power distribution and collector systems

Key Features

  • Compact RMU structure for ring network distribution and feeder sectionalizing
  • Available in SF6, solid-insulated, or customized insulation architecture according to model
  • Suitable for urban distribution, renewable feeder interface, and compact substation integration
  • Project-oriented switching arrangement, protection options, and automation interfaces available
  • Space-efficient design for indoor or kiosk-based deployment
  • Supports export documentation and project-based configuration control

Optional Configurations

  • Rated current and short-time withstand current
  • Protection relay brand and function package
  • Incoming/outgoing feeder arrangement
  • Automation and communication interface
  • Cabinet dimensions, finish, and busbar layout
  • Accessory package and interlock scheme
  • Color, nameplate language, and document package
  • Ambient temperature, altitude, and installation condition adaptation

Questions fréquemment posées

Please send us your required rated voltage, current, feeder configuration, protection functions, communication requirements, and installation conditions for the sf6 gas insulated ring main unit (rmu) three-phase. Our team can recommend a suitable configuration and provide a quotation based on your project requirements.

The equipment can be produced according to IEC standards and customer technical specifications. Routine inspection records, wiring documents, component lists, and factory test information can be provided before shipment. Optional configurations for communication, enclosure protection, and project-specific electrical interfaces are available upon request.

Minimum order quantity is 1 Set. The product is prepared for export shipment with suitable packing and handling arrangements based on destination, lifting, and transport requirements. Technical documents, test reports, labeling confirmation, and pre-shipment coordination can be supplied according to order requirements. OEM/ODM support and project-based coordination are available for qualified inquiries.

Normes et conformité

The equipment can be produced according to IEC standards and customer technical specifications. Routine inspection records, wiring documents, component lists, and factory test information can be provided before shipment. Optional configurations for communication, enclosure protection, and project-specific electrical interfaces are available upon request.

Emballage, livraison et service

The product is prepared for export shipment with suitable packing and handling arrangements based on destination, lifting, and transport requirements. Technical documents, test reports, labeling confirmation, and pre-shipment coordination can be supplied according to order requirements. OEM/ODM support and project-based coordination are available for qualified inquiries.

Please send us your required rated voltage, current, feeder configuration, protection functions, communication requirements, and installation conditions for the sf6 gas insulated ring main unit (rmu) three-phase. Our team can recommend a suitable configuration and provide a quotation based on your project requirements.

Prêt à procéder ?

Demander un devis pour 24kV SF6 Gas Insulated Ring Main...

Partagez votre périmètre de projet et nous vous répondrons sous 24 heures.